Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UHVHW provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems in high-voltage environments. The SU6000RT4UHVHW has a 6kVA/5400W capacity and hardwire output.
With its detachable PDU with bypass switch, the SU6000RT4UHVHW is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation.
UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHVHW’s runtime can be expanded with optional external battery packs.
The SU6000RT4UHVHW features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.
An LCD display with LED indicators enables IT personnel to operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.
The SU6000RT4UHVHW features a USB port and a DB9 ports for comprehensive network power monitoring and control. Network management card options available.
The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory.
The SU6000RT4UHVHW comes with $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment.
Features:
- Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing
- Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
- Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
- Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment
- Hardwire input and output connections supported
- Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
- Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (1 required for SU6000RT4UHVHW)
- Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UHVHW)
- Maximum installed rack depth of only 20.7 in. / 52.6cm inches
- Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode
- Corrects brownouts to 156V at full load (100V at 50% load or less)
- Corrects overvoltages to 290V at full load (300V at 90% load or less)
- Supports 50/60Hz operation for worldwide frequency compatibility
- Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
- High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
- Network-grade AC surge and noise suppression
- Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and network management card options
- Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD
- Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
- HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
- USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from poweralert
- Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major
- UPS functions with support for a variety of control options to support advanced UPS settings and configurations
- LED/LCD display panel rotates for viewing in rackmount or tower configurations
- Supports Emergency Power Off (EPO) via built-in interface
- Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
- BP192V12-3U external battery packs are field replaceable and hot swappable
- Intelligent battery management system with temperature-compensated charging extends battery life
- Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
- Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Package Includes
- Hot-swappable UPS Power Module
- SUPDMB6KHW Detachable PDU with Maintenance Bypass Switch
- 1 x 6-ft. USB Cable
- 1 x 6-ft. DB9 Cable
- 4-Post Rackmount Hardware
Specifications
OVERVIEW
- UPC Code: 037332157089
- UPS Type: On-Line
OUTPUT
- Output Volt Amp Capacity (VA): 6000
- Output kVA Capacity (kVA): 6
- Output Watt Capacity (Watts): 5400
- Output kW Capacity (kW): 5.4
- Power Factor : 0,9
- Crest Factor : 3:1
- Nominal Voltage Details: Voltage selection via front panel LCD interface
- Frequency Compatibility: 50 / 60 Hz
- Frequency Compatibility Details: Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
- Output Voltage Regulation (Line Mode): +/- 2%
- Output Voltage Regulation (Economy Line Mode): +/- 10%
- Output Voltage Regulation (Battery Mode): +/- 2%
- Output Receptacle Details: Hardwire input and output connections are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
- Output AC Waveform (AC Mode): Pure Sine wave
- Output AC Waveform (Battery Mode): Pure Sine wave
- Output Capacity Details: Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared
- Nominal Output Voltage(s) Supported: 200V; 208V; 220V; 230V; 240V
- Output Receptacles: Hardwire
- Individually Controllable Load Banks : No
INPUT
- Rated input current (Maximum Load): 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
- Nominal Input Voltage(s) Supported: 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
- UPS Input Connection Type: Hardwire
- UPS Input Connection Description: Supports North American 208/240V input (L1,L2,G) or International 230/220/240V (L,N,PE) input wiring
- Recommended Electrical Service: 40A (200/208v); 30A (220/230/240v)
Input Phase: Single-Phase
BATTERY
- Full Load Runtime (min.) : 2 minutes (5400 watts)
- Half Load Runtime (min.) : 8.5 minutes (2700 watts)
- Expandable Battery Runtime: Runtime is expandable with external battery packs
- External Battery Pack Compatibility : BP192V1037C-1PH ; BP192V12-3U ; BP192V1407C-1PH ; BP192V557C-1PH ; BP192V787C-1PH ; BP192V5RT2U (limit 1)
- DC System Voltage (VDC): 192
- Battery Recharge Rate (Included Batteries): 6 hours from 10% to 90% (typical, full load discharge)
- Internal UPS Replacement Battery Cartridge: RBC5-192
- Battery Access: Front panel battery access door
- Battery Replacement Description: Hot-swappable, user replaceable internal batteries
- Expandable Runtime: Yes
VOLTAGE REGULATION
- Voltage Regulation Description: Online, double-conversion power conditioning
- Overvoltage Correction : Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
- Undervoltage Correction : Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
USER INTERFACE, ALERTS & CONTROLS
- Front Panel LCD Display: Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring
- options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
- Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
- Alarm Cancel Operation: Alarm cancel switch
- Audible Alarm: Unique audible alarms for all major UPS, environmental and power conditions (see manual)
- LED Indicators: 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
SURGE / NOISE SUPPRESSION
- UPS AC Suppression Joule Rating: 2595
- UPS AC Suppression Response Time: Instantaneous
- EMI / RFI AC Noise Suppression : Yes
PHYSICAL
- Cooling Method: Fans
- Included Mounting Accessory Description: 4 post rackmount installation accessories included
- Installation Form Factors Supported with Optional Accessories: 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )
- Maximum Device Depth (cm): 52.58
- Maximum Device Depth (mm): 526
- Minimum Required Rack Depth with External Battery Pack (cm): 73
- Minimum Required Rack Depth with External Battery Pack (in.): 28.67
- Minimum Required Rack Depth without External Battery Pack (cm): 53
- Minimum Required Rack Depth without External Battery Pack (in.): 20.67
- Primary Form Factor: Rackmount
- Primary UPS Depth (mm): 525
- Primary UPS Height (mm): 174
- Primary UPS Width (mm): 445
- Rack Height: 4U
- Shipping Dimensions (hwd / cm): 32.26 x 59.94 x 73.91
- Shipping Weight (kg): 70.99
- UPS Housing Material: Steel
- UPS Power Module Dimensions (hwd, cm): 17.40 x 44.45 x 52.50
- UPS Power Module Weight (kg): 52.71
ENVIRONMENTAL
- Operating Temperature Range: +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
- Storage Temperature Range: +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
- Relative Humidity: 0 to 95%, non-condensing
- AC Mode BTU / Hr. (Full Load) : 1767
- AC Economy Mode BTU / Hr. (Full Load): 768
- Battery Mode BTU / Hr. (Full Load) : 2279
- AC Mode Efficiency Rating (100% Load): 90%
- AC Economy Mode Efficiency Rating (100% Load): 96%
- Operating Elevation (ft.): 0-3000m (0 to 10,000 ft.)
- Audible Noise: 60 dBA at front side 1 meter
- Operating Elevation (m): 0-3000 m
COMMUNICATIONS
- Network Management Cards: SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD
- Network Monitoring Port Description: Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
- PowerAlert Software: For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at poweralert
- Communications Cable: USB, DB9 serial and EPO cables included
- WatchDog Compatibility: Yes
- Communications Interface: USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
LINE / BATTERY TRANSFER
- Transfer Time : No transfer time (0 ms.) in online, double-conversion mode
- Transfer Time (Economy Mode) : 8 ms. typical power failure response in optional economy mode
- Low Voltage Transfer to Battery Power (Setpoint): 156V (full load) / 100V (50% load or less, derates linearly)
- High Voltage Transfer to Battery Power (Setpoint): 280V (full load) / 300V (90% load or less)
SPECIAL FEATURES
- Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
- High Availability UPS Features: Automatic inverter bypass; Battery Independent Restart; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch
- Green Energy-Saving Features: High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
CERTIFICATIONS
- UPS Certifications: Tested to UL1778 (USA); Tested to CSA (Canada); CE; Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
- UPS Certification Details: IEC 61000-4-5 1995 B Surge Immunity
WARRANTY
- Product Warranty Period (Worldwide): 2-year limited warranty