| General Specifications | ||
| AC Current via Jaw | ||
| Range | 999.9 A | |
| Resolution | 0.1 A | |
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |
| 2.5% ±5 digits (100-500 Hz) | ||
| Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |
| 2.5 @ 600 A | ||
| Add 2% for C.F. >2 | ||
| AC Current via Flexible Current Probe | ||
| Range | 2500 A | |
| Resolution | 0.1 A (? 600 A) | |
| 1 A (? 2500 A) | ||
| Accuracy | 3% ±5 digits (5 – 500 Hz) | |
| Crest Factor (50/60Hz) | 3.0 at 1100 A | |
| 2.5 at 1400 A | ||
| 1.42 at 2500 A | ||
| Add 2% for C.F. > 2 | ||
| Position Sensitivity | ||
![]() |
||
| i2500-10 Flex | i2500-18 Flex | |
| A | ||
| Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| Error | ±0.5 % | ±0.5 % |
| B | ||
| Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| Error | ±1.0 % | ±1.0 % |
| C | ||
| Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| Error | ±2.0 % | ±2.0 % |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field
The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity. FIND THE CAUSE OF DIFFICULT PROBLEMSThe 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it. Measure:
WORK SAFELY AND CONVENIENTLYThe 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool. The included iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:
â—† Measures AC/DC current with included iFlex current probe â—† VFD low pass filter for accurate measurements of non-linear signals â—† Remotely log, trend, and monitor to pinpoint intermittent faults â—† Inrush measurement to filter out the noise and capture starting current |
||