FLUKE | True-Rms Clamp Meter With Iflex | 376 FC

QAR 2,153.00
Availability: In stock
Brand: FLUKE
Barcode: 376 FC

Explore other bestsellers in
Building Materials & Hand Tools

PRODUCT DESCRIPTION

General Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% -5 digits (10 Hz to 100 Hz)
2.5% -5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (? 600 A)
1 A (? 2500 A)
Accuracy 3% -5 digits (5 -" 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
i2500-10 Flex i2500-18 Flex
A
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error -0.5 % -0.5 %
B
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error -1.0 % -1.0 %
C
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error -2.0 % -2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.

FIND THE CAUSE OF DIFFICULT PROBLEMS

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.

Measure:

  • Voltage to 1000 V AC or DC
  • Resistance to 60 k? with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV DC measurement range to interface with other accessories
  • 1000 ?F capacitance measurement

WORK SAFELY AND CONVENIENTLY

The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.

The included iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:

  • Expands the measurement range to 2500 A AC
  • Allows frequency measurement to 500 Hz with body jaw and iFlex

- Measures AC/DC current with included iFlex current probe

- VFD low pass filter for accurate measurements of non-linear signals

- Remotely log, trend, and monitor to pinpoint intermittent faults

- Inrush measurement to filter out the noise and capture starting current

Reviews

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Specifications

Type FLUKE
Vendor Prompt Engineering & Trading Service CO.W.L.L
Barcode 376 FC

Description

General Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% -5 digits (10 Hz to 100 Hz)
2.5% -5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (? 600 A)
1 A (? 2500 A)
Accuracy 3% -5 digits (5 -" 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
i2500-10 Flex i2500-18 Flex
A
Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)
Error -0.5 % -0.5 %
B
Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)
Error -1.0 % -1.0 %
C
Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)
Error -2.0 % -2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field

The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.

FIND THE CAUSE OF DIFFICULT PROBLEMS

The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.

Measure:

  • Voltage to 1000 V AC or DC
  • Resistance to 60 k? with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV DC measurement range to interface with other accessories
  • 1000 ?F capacitance measurement

WORK SAFELY AND CONVENIENTLY

The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.

The included iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:

  • Expands the measurement range to 2500 A AC
  • Allows frequency measurement to 500 Hz with body jaw and iFlex

- Measures AC/DC current with included iFlex current probe

- VFD low pass filter for accurate measurements of non-linear signals

- Remotely log, trend, and monitor to pinpoint intermittent faults

- Inrush measurement to filter out the noise and capture starting current