Explore other bestsellers in
Construction & Industrial
| Voltage DC | Accuracy1 | -±(0.09% + 2) |
| Max. resolution | 0.1 mV | |
| Maximum | 1000 V | |
| Voltage AC | Accuracy1 | -±(1.0% + 3) |
| Max. resolution | 0.1 mV | |
| Maximum | 1000 V | |
| Current DC | Accuracy1 | -±(1.0% + 3) |
| Max. resolution | 0.01 mA | |
| Maximum | 0.416666667 | |
| Current AC | Accuracy1 | -±(1.5% + 3) |
| Max. resolution | 0.01 mA | |
| Maximum | 0.416666667 | |
| Resistance | Accuracy1 | -±(0.9% + 1) |
| Max. resolution | 0.1 -© | |
| Maximum | 50 M-© | |
| Capacitance | Accuracy1 | -±(1.2% + 2) |
| Max. resolution | 1 nF | |
| Maximum | 10,000 --F | |
| Frequency | Accuracy1 | -±(0.1% + 1) |
| Max. resolution | 0.01 Hz | |
| Maximum | 100 kHz | |
| Temperature | Accuracy1 | -±(1.0% + 10) |
| Max. resolution | 0.1-°C | |
| Range | -40-°C / 400-°C | |
| 1. Accuracies are best accuracies for each function | ||
| Environmental Specifications | ||
| Operating temperature | -10-°C to +50-°C | |
| Storage temperature | -30-°C to +60-°C | |
| Humidity (without condensation) | 0% -" 90% (0-°C -" 35-°C) | |
| 0% -" 70% (35-°C -" 50-°C) | ||
| Safety Specifications | ||
| Overvoltage category | EN 61010-"1 to 1000 V CAT III | |
| EN 61010-"1 to 600 V CAT IV | ||
| Agency approvals | UL, CSA, T--V listed and VDE Pending | |
| Mechanical and General Specifications | ||
| Size | 43 x 90 x 185 mm | |
| Weight | 420 g | |
| Warranty | Lifetime | |
| Battery life | Alkaline ~200 hours typical, without backlight |
Product overview: Fluke 179 True-RMS Digital Multimeter
The Fluke 179 True-RMS Digital Multimeter is the industry-standard troubleshooting tool for electrical and electronic systems. This incredibly versatile multimeter makes a perfect front-line troubleshooting tool with an input protection rating of CAT III 1000 V, CAT IV 600 V. The built-in temperature measurement with the included thermocouple, analog bar graph and backlit digital display make it easier to take the measurements you need.
A full set of basic and advanced troubleshooting capabilities including:
What's in the box:
-- 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 M„-; capacitance to 10,000 -1-4F, frequency to 100 kHz; temperature from -40 „- to 400 „-
-- Robust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording
-- Backlit digital display, analog bar graph, and built-in temperature measurements with included thermocouple
| Voltage DC | Accuracy1 | -±(0.09% + 2) |
| Max. resolution | 0.1 mV | |
| Maximum | 1000 V | |
| Voltage AC | Accuracy1 | -±(1.0% + 3) |
| Max. resolution | 0.1 mV | |
| Maximum | 1000 V | |
| Current DC | Accuracy1 | -±(1.0% + 3) |
| Max. resolution | 0.01 mA | |
| Maximum | 0.416666667 | |
| Current AC | Accuracy1 | -±(1.5% + 3) |
| Max. resolution | 0.01 mA | |
| Maximum | 0.416666667 | |
| Resistance | Accuracy1 | -±(0.9% + 1) |
| Max. resolution | 0.1 -© | |
| Maximum | 50 M-© | |
| Capacitance | Accuracy1 | -±(1.2% + 2) |
| Max. resolution | 1 nF | |
| Maximum | 10,000 --F | |
| Frequency | Accuracy1 | -±(0.1% + 1) |
| Max. resolution | 0.01 Hz | |
| Maximum | 100 kHz | |
| Temperature | Accuracy1 | -±(1.0% + 10) |
| Max. resolution | 0.1-°C | |
| Range | -40-°C / 400-°C | |
| 1. Accuracies are best accuracies for each function | ||
| Environmental Specifications | ||
| Operating temperature | -10-°C to +50-°C | |
| Storage temperature | -30-°C to +60-°C | |
| Humidity (without condensation) | 0% -" 90% (0-°C -" 35-°C) | |
| 0% -" 70% (35-°C -" 50-°C) | ||
| Safety Specifications | ||
| Overvoltage category | EN 61010-"1 to 1000 V CAT III | |
| EN 61010-"1 to 600 V CAT IV | ||
| Agency approvals | UL, CSA, T--V listed and VDE Pending | |
| Mechanical and General Specifications | ||
| Size | 43 x 90 x 185 mm | |
| Weight | 420 g | |
| Warranty | Lifetime | |
| Battery life | Alkaline ~200 hours typical, without backlight |
Product overview: Fluke 179 True-RMS Digital Multimeter
The Fluke 179 True-RMS Digital Multimeter is the industry-standard troubleshooting tool for electrical and electronic systems. This incredibly versatile multimeter makes a perfect front-line troubleshooting tool with an input protection rating of CAT III 1000 V, CAT IV 600 V. The built-in temperature measurement with the included thermocouple, analog bar graph and backlit digital display make it easier to take the measurements you need.
A full set of basic and advanced troubleshooting capabilities including:
What's in the box:
-- 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 M„-; capacitance to 10,000 -1-4F, frequency to 100 kHz; temperature from -40 „- to 400 „-
-- Robust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording
-- Backlit digital display, analog bar graph, and built-in temperature measurements with included thermocouple
No reviews yet. Be the first to share your experience!
for FLUKE | 179 True-RMS Digital Multimeter